<LOGO>
FM Transmitter Measurement Report
Created: 2026-08-20 05-18-34
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
105.50 MHz 5/5, 67 dBuV BOOST FI
Pilot RDS Phase Difference
6.5 kHz 3.3 kHz 25 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 68 kHz 11858 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,0 dBr 5,72 dBr 7,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"BOOST FI" 4E31 10 (Pop M) 1 0 1 1 5:18, 20.08.2026
RT
" Finnland (Reg Test D "
AF EON
92.8, 96.6, 103.9, 105.5 MHz -
FM Scope Max at: 68 kHz MIN: 9 kHz % above 76 kHz: 0,0000 Acquired: 2026.08.20 5.17.30 Total samples: 11858 Equivalent time: 0:09:52 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 7,4 dBr MIN: 3,0 dBr AVE: 5,72 dBr % above 12,2 dBr: 0,0 Last value: 5,9 dBr (2026.08.20 5.17.30) 05.04 05.06 05.08 05.10 05.12 05.14 05.16 0 2 4 6 8 Pm [dBr]